Rated 4.8 on Trustpilot
Read Reviews


·
Commercial & New Build
What Affects the Cost of Commercial Solar Panels?
No two commercial solar systems cost the same. The price depends on system size, the roof, access, electrical and grid work, batteries and the funding route. Here is how each factor works.
By
Solar Panels London
·
Last reviewed
The cost of a commercial solar system depends mainly on its size, the roof it goes on, how difficult the roof is to access safely, the electrical and grid connection work, whether a battery is included, and how you fund it. Two buildings with the same roof area can have very different prices because of access, roof condition or grid constraints. The only reliable way to know the cost for your site is an assessment based on your building and your electricity data.
This guide explains each factor so you can see what drives a commercial quote, and which decisions are in your control. For how we assess a site, see our commercial solar assessment page.
Key points
System size has the biggest effect on the total, but larger systems usually cost less per panel.
Roof type, condition and structure decide the mounting system and any preparation work.
Access and safety measures can be a significant part of the cost on tall or fragile roofs.
Grid connection requirements can add network work, delay or an export limit.
Batteries add cost and are worth it only where they move enough solar into hours you use it.
Commercial installations carry standard-rate VAT, which most VAT-registered businesses can reclaim.
Buying outright, using a PPA, or claiming capital allowances all change the cost to your business.
System size
The number of panels drives the cost of panels, mounting, inverters and labour. Some costs are fixed, such as design, the site survey, grid applications and commissioning, so they are spread across more panels on a larger system. That is why the cost per panel generally falls as systems get bigger.
The right size isn’t simply the largest that fits. It depends on how much electricity your site uses in daylight, how much the network will let you export, and whether a battery is part of the design. Oversizing a system that mostly exports is rarely the best use of money.
The roof
The roof affects the mounting system and how much preparation is needed:
Profiled metal roofs usually take rail systems fixed or clamped to the sheet.
Standing seam roofs can often use clamps that don’t penetrate the sheet.
Flat roofs usually take ballasted systems, which need more components and more structural checking. We use Van der Valk mounting on flat roofs.
Pitched tiled or slate roofs on smaller commercial buildings use hooks under the tiles. We use Van der Valk or K2 mounting on pitched roofs.
Roof condition matters too. If the covering is near the end of its life, it is often cheaper overall to replace it before the panels go on. Fibre cement roofs that may contain asbestos add survey work and can make roof replacement the sensible first step. Our guide to solar on warehouse and industrial roofs explains these checks.
Structure
Some buildings need a structural engineer’s report to confirm the roof can carry the extra load, including wind uplift. If it can’t, strengthening work or a lighter mounting system may be needed, or the panel layout may change. This is one of the factors that can only be known after a survey.
Access and safety

Working safely at height is a fixed part of every job. Depending on the building, access can involve scaffolding, edge protection, safety netting, staging over fragile areas, mobile elevating work platforms (MEWPs) and hoists or cranes to lift materials. Taller buildings, roofs with many rooflights, restricted sites and busy yards all add to this. Our guide to scaffolding for solar installations in London explains how access is planned.
Out-of-hours working, phased installation to keep part of a building in use, and strict site rules can also affect the programme and cost.
Electrical work
The electrical side includes cable runs from the roof to the inverters, the inverters themselves, protection and isolation, and the connection into your switchgear. Costs rise with long cable runs, inverters that need to sit far from the array, or switchgear that needs upgrading to accept the new supply. Most commercial sites have a three-phase supply, but older boards may need work.
The grid connection

Most commercial systems need a G99 application to the network operator. The operator may approve the full export, limit how much you can export, or require network works before connection. Where works are needed, the operator sets the cost and timetable, and that can change the size of system that makes sense. Our guide to commercial solar and G99 explains the process.
Request a commercial solar assessment
Tell us about your premises and we’ll call you back to talk through solar and battery storage for your site.
We install across London and up to around 50 miles out.
Batteries
A battery adds cost, so it should earn its place. It helps where a site generates more than it uses during the day and has significant use in the evening or overnight, or where an export limit would otherwise waste generation. Battery size, the inverter arrangement, where it is installed and fire safety requirements all affect the cost. Our commercial battery storage page and our guide to battery storage for businesses explain when a battery is worth adding.
Monitoring and maintenance
Commercial systems should have monitoring so faults are picked up quickly, and a planned maintenance regime to keep them performing and meet insurer expectations. These are ongoing costs to factor in alongside the installation. Our commercial solar maintenance page explains what that involves.
VAT, tax and funding
Commercial solar installations carry standard-rate VAT. The zero rate applies only to installations in residential accommodation, as our guide to VAT on solar panels and batteries explains. Most VAT-registered businesses can reclaim it.
The cost to your business also depends on how you fund it:
Buying outright means paying upfront and keeping all the savings.
A power purchase agreement (PPA) means a funder pays for and maintains the system, and you pay a fixed rate for the solar electricity you use. We offer PPAs through a funding partner.
Capital allowances can reduce the tax cost of buying a system. See our guide to capital allowances for solar panels.
Business rates. Plant and machinery used for onsite renewable generation and storage is currently exempt from business rates in England until March 2035.
How to get an accurate quote
Send us the site address, who owns the roof, your half-hourly electricity data or recent bills, and any roof drawings or surveys you have. We assess the roof, structure, electrics and grid position before proposing a system, and we set out purchase and PPA options side by side. Our guide to the commercial solar installation process explains each stage.
FAQs
Why do commercial solar quotes vary so much?
Because quotes can include different things. Check whether access, structural checks, grid applications, network works, monitoring and maintenance are included, and whether the system size has been matched to your usage.
Is a bigger system always better value?
Not always. Larger systems usually cost less per panel, but if much of the extra generation is exported, or the network limits export, the extra panels may add less value than they cost.
Do you publish prices?
No. Every commercial system is designed for its site, so we quote after an assessment rather than publishing figures that may not apply to your building.
Request a commercial solar assessment
Tell us about your premises and we’ll call you back to talk through solar and battery storage for your site.
We install across London and up to around 50 miles out.
Latest Articles
Ready to Start Saving with Solar?
Get your free no-obligation quote today. Our experts will design the perfect system for your home.
Free Home Survey
MCS Certified
Reply in 1 Working Day
Quick Links
Services
Contact
© 2026 Solar Panels London. All rights reserved.
SOLAR PANELS LONDON (SPL) LIMITED, registered in England and Wales, company number 14360308. Registered Office, 20 Rosslyn Crescent, Luton, LU3 2AU. SOLAR PANELS LONDON (SPL) LIMITED is an Introducer Appointed Representative of Shermin Finance Limited, FRN 727594, company number 01276121. Registered Office, Homeserve, Cable Drive, Walsall, WS2 7BN. Shermin Finance Limited act as a credit broker and is not a lender. Credit is subject to status and affordability.