Growatt Inverter Fault Codes: What They Mean and What to Do

A Growatt fault message doesn’t always mean the inverter has failed. Here is what the common messages mean, what you can check yourself, and when it needs an engineer.

By

Solar Panels London

·

Last reviewed

Growatt inverters show two kinds of fault: system faults with names like PV Isolation Low or No AC Connection, which usually point to a problem outside the inverter, and numbered errors such as Error 102 or Error 117, which usually point to the inverter’s own electronics. Grid faults often clear by themselves. Insulation and leakage faults, and numbered errors that come back after a restart, need an engineer.

This guide uses the fault names in Growatt’s troubleshooting guidance for its single-phase string inverters, such as the TL and MTL ranges. Messages vary between models and generations, so the manual for your inverter is the final word. Growatt’s guidance on internal faults ends with a board or inverter replacement, which is work for a qualified engineer.

Key points

  • No AC Connection, AC V Outrange and AC F Outrange relate to the mains supply. Check for a power cut or a tripped breaker first.

  • PV Isolation Low and Residual I High point to an insulation or earth leakage problem on the solar side. One on a damp morning can clear; repeats need an engineer.

  • Over temperature means the inverter is too hot. Ventilation and direct sun are the usual causes.

  • Numbered errors in the 100s relate to the inverter’s internal electronics. If a restart doesn’t clear them, the inverter usually needs repair or replacement.

  • Never open the inverter, and don’t switch DC isolators unless an engineer has told you how and in which order.

First: is the fault still showing?

Check the inverter display or the Growatt app. Note the exact message, the date and time, and whether it keeps coming back. Photograph the label on the side of the inverter with the model and serial number, because the fault list depends on the model.

Illustration of three possible sources of an inverter fault: the grid, the solar panels and the inverter itself

Grid faults: usually the supply, not the inverter

  • No AC Connection: the inverter can’t see the mains supply. Expected in a power cut. If the house has power, check whether the solar breaker in your consumer unit has tripped.

  • AC V Outrange: the grid voltage is outside the range the inverter accepts.

  • AC F Outrange: the grid frequency is outside the accepted range.

UK connection rules require inverters to disconnect when the grid goes outside set limits, so occasional grid faults are the inverter doing its job. If AC V Outrange keeps appearing on sunny afternoons, the cause is often high local voltage. Our guide to inverters that shut down on sunny days explains what to do.

Insulation and leakage faults: call an engineer

  • PV Isolation Low: the insulation between the solar wiring and earth has dropped too low.

  • Residual I High: leakage current to earth is higher than the inverter allows.

  • Output High DCI: the inverter has detected too much DC in its AC output. Growatt’s guidance is that the inverter needs replacing if this keeps appearing.

A single insulation fault on a wet morning that clears as the day warms up isn’t unusual. Repeated faults mean something in the DC wiring needs finding, such as water in a connector or damaged cable. Solar panels produce voltage whenever there is daylight, so testing them is work for an engineer with the right equipment. If your consumer unit keeps tripping as well, read our guide to solar panels tripping the fuse box.

Illustration of an engineer's tester next to the cable connectors under a solar panel

Temperature

Over temperature means the inverter has got too hot and is protecting itself. Check that nothing is blocking the air around it and that it isn’t in direct afternoon sun or a hot loft. If it happens often, the location may need changing.

Numbered errors: the inverter itself

Growatt’s guidance for its TL and MTL inverters lists these among the internal errors:

  • Error 101, 102 and 121: the inverter’s processors aren’t communicating or don’t agree with each other.

  • Error 116: a memory (EEPROM) fault.

  • Error 117: a relay fault.

  • Error 118: the inverter’s model setting has failed to load.

  • Error 119: a possible fault in the inverter’s own earth leakage protection.

  • Error 120: a current sensor fault.

  • Error 122: the internal bus voltage is out of range.

For most of these, Growatt suggests a restart first, and if the error persists, replacing the control board or the inverter. A safe restart means switching things off and on in the right order, which differs between models, so ask an engineer to talk you through it rather than working from a forum post. An internal error that comes straight back after a restart usually means the inverter needs replacing.

Book a solar system inspection

Tell us what’s happening and one of our team will call you back to arrange a visit.

We install across London and up to around 50 miles out.

No obligation. We’ll call you back within one working day (Mon–Fri, 9am–5pm). We only use your details to deal with your enquiry. See our privacy policy.

Repair or replace?

On a newer Growatt still under warranty, the first call is to your installer, who can raise a claim with the manufacturer. On an older unit out of warranty, a repair is rarely worth it. A replacement keeps your panels and cabling and swaps only the inverter, and if you have been thinking about a battery, a hybrid inverter can run both. We usually fit Solis, FoxESS or Hanchu equipment. Our page on inverter replacement explains the options, including on Feed-in Tariff systems.

What you can safely check yourself

  1. Is the fault active now, or only in the history?

  2. Note the exact message, the time and how often it appears.

  3. Has there been a power cut, a storm or work on your electricity supply?

  4. Check the solar breaker in the consumer unit. Reset it once if it has tripped; if it trips again, leave it off.

  5. Make sure nothing is blocking airflow around the inverter.

  6. Photograph the inverter label and the screen showing the fault.

If you smell burning, see scorch marks or hear crackling, switch off at the consumer unit if you can reach it safely, keep away from the equipment and call an engineer.

For other brands, see our guides to Sunsynk inverter fault codes and SolaX inverter fault codes.

Frequently asked questions

My Growatt says No AC Connection but the house has power. What should I check?

Check the solar breaker in your consumer unit. If it has tripped, reset it once. If it trips again, or the breaker is on and the fault stays, call an engineer.

Is PV Isolation Low dangerous?

A single fault on a damp morning that clears is common. Repeated or persistent faults mean an insulation problem on the solar side that should be found, because damaged DC cabling can be a fire risk.

Can a Growatt inverter be repaired?

Sometimes, while it is under warranty. For many internal errors, Growatt’s own guidance ends in a board or inverter replacement.

Do you work on Growatt systems?

Yes. We inspect and replace Growatt inverters on homes across London and up to around 50 miles out, whoever installed them.

Book a solar system inspection. If a Growatt fault keeps coming back, we’ll find the cause and tell you whether it needs a repair, a replacement or an upgrade.

Book a solar system inspection

Tell us what’s happening and one of our team will call you back to arrange a visit.

We install across London and up to around 50 miles out.

No obligation. We’ll call you back within one working day (Mon–Fri, 9am–5pm). We only use your details to deal with your enquiry. See our privacy policy.

Latest Articles

Ready to Start Saving with Solar?

Get your free no-obligation quote today. Our experts will design the perfect system for your home.

Free Home Survey

MCS Certified

Reply in 1 Working Day

© 2026 Solar Panels London. All rights reserved.

SOLAR PANELS LONDON (SPL) LIMITED, registered in England and Wales, company number 14360308. Registered Office, 20 Rosslyn Crescent, Luton, LU3 2AU. SOLAR PANELS LONDON (SPL) LIMITED is an Introducer Appointed Representative of Shermin Finance Limited, FRN 727594, company number 01276121. Registered Office, Homeserve, Cable Drive, Walsall, WS2 7BN. Shermin Finance Limited act as a credit broker and is not a lender. Credit is subject to status and affordability.