SolaX Inverter Fault Codes: What They Mean and What to Do
SolaX inverters show IE fault codes with a short name, such as Grid Lost Fault or Isolation Fault. Here is what the common ones mean, which usually clear on their own, and which need an engineer.
By
Solar Panels London
·
Last reviewed
SolaX inverters show faults as an IE code with a short name, such as IE 02 Grid Lost Fault or IE 13 Isolation Fault, on the screen and in the SolaXCloud app. Grid faults are usually caused by the supply and clear on their own. Battery faults point to the battery’s voltage or connection. Isolation faults, where insulation between the DC side and earth has dropped, need an engineer. We inspect SolaX systems and, where replacement is needed, usually upgrade to Solis, FoxESS or Hanchu equipment.
Key points
Grid faults (IE 02, IE 03, IE 04) are usually the supply and clear on their own.
An isolation fault (IE 13) needs an engineer. Don’t keep resetting it or touch the wiring.
An EPS overload (IE 16) means too much is connected to the backup output.
Codes vary by model and firmware, so always check the manual for yours.
The codes below are taken from SolaX’s own published guide, which uses the X3-Ultra as its example.
Grid faults: usually the supply

IE 02 Grid Lost Fault. The inverter can’t detect the grid. Wait for the supply to return, and check the solar breaker and AC isolator are on. If the power is on and the fault stays, contact your installer.
IE 03 Grid Volt Fault. The grid voltage is out of range. SolaX advises waiting for it to return to normal and checking the recorded voltage in SolaXCloud. If it keeps happening, the voltage needs checking. Our guide to why an inverter shuts down on sunny days explains high-voltage trips.
IE 04 Grid Freq Fault. The grid frequency is out of range. Usually brief. SolaX advises not resetting during an active grid problem.
Panel and DC faults: call an engineer
IE 05 PV Volt Fault. The voltage from the panels is above the allowed range, usually a design or wiring problem. Don’t handle the PV connections.
IE 13 Isolation Fault. An insulation or earth fault, possibly on the DC side. SolaX advises against repeated resets or touching the wiring, and recommends contacting a qualified installer.
Panels and their cables carry dangerous DC voltage whenever there is daylight. Don’t open the inverter or work on isolators or roof cables.
Battery faults
IE 07 Bat Volt Fault. Battery voltage is outside the normal range. Check the battery’s charge level and any BMS warnings in the app.
IE 15 Bat Con Dir Fault. The battery connection may be the wrong way round. This needs an installer, and you shouldn’t restart repeatedly.
Our guides to why a battery isn’t charging and why a battery isn’t discharging cover other battery problems.
Book a solar system inspection
Tell us what’s happening and one of our team will call you back to arrange a visit.
We install across London and up to around 50 miles out.
Overload faults

IE 01 TZ Protect Fault. Overcurrent protection has tripped. Wait briefly and reduce any load on the backup output.
IE 16 EPS Overload Fault. The backup (EPS) output is overloaded. Switch off high-power appliances on the backup circuit. Our guide to what keeps working in a power cut explains backup circuits.
IE 17 Overload Fault. Overload while connected to the grid. Reduce the load before restarting. If nothing large is connected, it needs checking.
Faults that point to the inverter itself
Relay, sensor or memory faults suggest an internal problem. SolaX advises against resetting them repeatedly. If one keeps returning, the inverter usually needs replacing.
What you can safely check yourself
Note the code, its name and when it appeared.
Check the solar breaker in your consumer unit and the AC isolator are on.
Check for a power cut in your area.
Check the battery’s charge level and any warnings in SolaXCloud.
Make sure nothing is blocking the inverter’s ventilation.
Repair or replace?
We diagnose the fault first, checking the panels, battery and cabling as well as the inverter. If the inverter or battery has failed and is out of warranty, a new hybrid inverter and battery gives you a supported system with new warranties. We usually fit Solis, FoxESS or Hanchu. Our Solis guide and page on inverter replacement explain the options.
Frequently asked questions
My SolaX shows Grid Lost Fault but the house has power. Why?
The inverter’s AC supply may be switched off at the breaker or isolator, or a connection may be loose. Check both. If they’re on, an engineer should check the AC connection.
Is an isolation fault dangerous?
It means the insulation between the DC side and earth has dropped. Don’t touch the panels, cables or isolators, and have it tested.
Can I clear a SolaX fault from the app?
Many faults clear on their own. Some need a restart in the order the manual shows. If a fault keeps returning, the cause needs finding.
Do you work on SolaX systems you didn’t install?
Yes. We inspect and diagnose systems whoever installed them. For other brands, see our guides to Sunsynk, Growatt and Huawei fault codes.
Get your inverter checked
Book a solar system inspection and send us the fault code and a photo of the inverter label.
Book a solar system inspection
Tell us what’s happening and one of our team will call you back to arrange a visit.
We install across London and up to around 50 miles out.
Latest Articles
Ready to Start Saving with Solar?
Get your free no-obligation quote today. Our experts will design the perfect system for your home.
Free Home Survey
MCS Certified
Reply in 1 Working Day
Quick Links
Services
Contact
© 2026 Solar Panels London. All rights reserved.
SOLAR PANELS LONDON (SPL) LIMITED, registered in England and Wales, company number 14360308. Registered Office, 20 Rosslyn Crescent, Luton, LU3 2AU. SOLAR PANELS LONDON (SPL) LIMITED is an Introducer Appointed Representative of Shermin Finance Limited, FRN 727594, company number 01276121. Registered Office, Homeserve, Cable Drive, Walsall, WS2 7BN. Shermin Finance Limited act as a credit broker and is not a lender. Credit is subject to status and affordability.