Huawei Inverter Fault Codes: What They Mean and What to Do
Huawei SUN2000 inverters show numbered alarms in the FusionSolar app. Here is what the common ones mean, which are usually the grid rather than your system, and which need an engineer.
By
Solar Panels London
·
Last reviewed
Huawei SUN2000 inverters report problems as numbered alarms, shown in the FusionSolar app and on the inverter’s lights. Many are grid alarms, such as voltage or frequency out of range, which usually clear on their own. Others, such as low insulation resistance or abnormal residual current, point to a possible fault in the panels or cabling and need an engineer. A device fault that won’t clear after a restart usually means the inverter itself has failed. We inspect Huawei systems and, where replacement is needed, usually upgrade to Solis, FoxESS or Hanchu equipment.
Key points
Huawei classes alarms as major, minor or warning. A major alarm shuts the inverter down and disconnects it from the grid.
Grid voltage and frequency alarms are usually caused by the supply, not your inverter.
Insulation, residual current and grounding alarms need an engineer. Don’t touch the DC cabling.
A device fault that comes back after a restart usually means the inverter has failed.
Alarm numbers and names can vary slightly between models, so check the manual for yours.
How Huawei alarms work
Each alarm has a number, a name and a severity. According to Huawei’s documentation, a major alarm means the inverter shuts down and disconnects from the grid, a minor alarm means some components are faulty but the inverter can still feed power to the grid, and a warning means output is reduced because of something outside the inverter.

Grid alarms: usually the supply
2032 Grid loss. The grid is down, or the AC circuit to the inverter is switched off or disconnected. Check the solar breaker and AC isolator are on.
2033 Grid undervoltage and 2034 Grid overvoltage. The grid voltage is outside the allowed range. Huawei says an occasional alarm is normally a brief grid problem and the inverter recovers on its own. If it happens often, the grid voltage needs checking. Our guide to why an inverter shuts down on sunny days explains high-voltage trips.
Grid frequency alarms. The frequency is outside the limits or changing too fast. Usually brief and caused by the grid.
Panel and cabling alarms: call an engineer
2001 High string input voltage. The voltage from the panels is above the inverter’s maximum, usually a design or wiring problem.
2011 String reverse connection. A string of panels is wired the wrong way round.
2051 Abnormal residual current. Leakage current to earth during operation.
2061 Abnormal grounding. The earth cable isn’t connected properly, or the neutral-to-earth voltage is too high.
2062 Low insulation resistance. The insulation between the panels or cabling and earth has dropped, for example from damage or water getting in. Huawei notes this can appear in damp weather. If it keeps coming back, it needs testing.
Don’t open the inverter, touch the DC cables or isolators, or change protection settings. These alarms need testing with proper equipment.

Book a solar system inspection
Tell us what’s happening and one of our team will call you back to arrange a visit.
We install across London and up to around 50 miles out.
Inverter alarms
2063 Overtemperature. The inverter is too hot. Check it isn’t in direct sun in a confined space, and that nothing is blocking airflow around it.
2064 Device fault. An internal fault. Huawei suggests switching off the AC and DC switches, waiting five minutes and switching back on. If it returns, the inverter usually needs replacing.
2065 Upgrade failed. A firmware update didn’t complete. It can usually be retried.
Monitoring unit faulty. The communication module has a problem. The inverter may still be generating. Our guide to getting a solar monitoring app back online can help.
Battery and meter alarms
On systems with a Huawei battery or power meter, alarms such as a faulty power collector or battery abnormal point to a communication problem with the meter or battery. Check the app for details and call an engineer if they don’t clear.
What you can safely check yourself
Note the alarm number, name and time in the app.
Check the solar breaker in your consumer unit and the AC isolator are on.
See whether the alarm clears on its own, and whether it happens at a particular time of day.
Make sure nothing is blocking the inverter’s ventilation.
If Huawei’s instructions suggest a restart, switch off AC and DC, wait five minutes, and switch back on in the order the manual shows.
Repair or replace?
We diagnose the fault first, checking the panels and cabling as well as the inverter. If the inverter itself has failed and is out of warranty, replacing it with a hybrid inverter lets you add a battery at the same time. We usually fit Solis, FoxESS or Hanchu. Our Solis guide and page on inverter replacement explain the options.
Frequently asked questions
My Huawei inverter shows Grid Loss but the house has power. Why?
The inverter’s AC supply may be switched off at the isolator or breaker, or a connection may have come loose. Check the solar breaker and isolator. If they’re on, an engineer should check the AC connection.
Is a low insulation resistance alarm dangerous?
It means the insulation between the DC side and earth has dropped. Don’t touch the panels, cables or isolators. Have it tested by an engineer, especially if it keeps coming back.
Can I clear a Huawei alarm from the app?
Many alarms clear on their own when the cause goes. A restart can clear some faults, but if an alarm keeps returning, the cause needs finding.
Do you work on Huawei systems you didn’t install?
Yes. We inspect and diagnose systems whoever installed them. For other brands, see our guides to Solis, FoxESS and Growatt fault codes.
Get your inverter checked
Book a solar system inspection and send us the alarm number and a photo of the inverter label.
Book a solar system inspection
Tell us what’s happening and one of our team will call you back to arrange a visit.
We install across London and up to around 50 miles out.
Latest Articles
Ready to Start Saving with Solar?
Get your free no-obligation quote today. Our experts will design the perfect system for your home.
Free Home Survey
MCS Certified
Reply in 1 Working Day
Quick Links
Services
Contact
© 2026 Solar Panels London. All rights reserved.
SOLAR PANELS LONDON (SPL) LIMITED, registered in England and Wales, company number 14360308. Registered Office, 20 Rosslyn Crescent, Luton, LU3 2AU. SOLAR PANELS LONDON (SPL) LIMITED is an Introducer Appointed Representative of Shermin Finance Limited, FRN 727594, company number 01276121. Registered Office, Homeserve, Cable Drive, Walsall, WS2 7BN. Shermin Finance Limited act as a credit broker and is not a lender. Credit is subject to status and affordability.