Sunsynk Inverter Fault Codes: What They Mean and What to Do

Sunsynk hybrid inverters show F codes when something goes wrong. Here is what the common ones mean, which are usually the grid or the battery, and which need an engineer.

By

Solar Panels London

·

Last reviewed

Sunsynk hybrid inverters show a fault code starting with F, such as F35 or F56, on the screen and in the app. Some are caused by the grid and clear on their own once the supply returns to normal. Some relate to the battery, such as low battery voltage or lost communication with the battery. Others, such as DC insulation or leakage current faults, point to a possible problem in the panels or cabling and need an engineer. We inspect Sunsynk systems and, where replacement is needed, usually upgrade to Solis, FoxESS or Hanchu equipment.

Key points

  • Grid faults such as F35, F42, F47 and F48 are usually the supply, not the inverter.

  • Battery faults such as F56 and F58 point to the battery’s charge level, its connection, or communication with it.

  • Insulation and leakage faults such as F23 and F24 need an engineer. Don’t touch the DC cabling.

  • Overcurrent and overload faults often mean too much is connected to the backup output.

  • Codes and names can vary between models and firmware, so check the manual for yours.

Grid faults: usually the supply

Illustration of fault types grouped into grid, panels, battery and inverter
  • F35 No AC grid. The inverter can’t see the grid. Check whether there is a power cut, and that the solar or inverter breaker and AC isolator are on.

  • F42 AC line low voltage. The grid voltage is below the allowed range. Usually a supply issue. If it happens often, an engineer should check the grid settings and connections.

  • F47 and F48 AC over and under frequency. The grid frequency is out of range. Usually brief and caused by the grid.

If your inverter trips on high grid voltage on sunny days, our guide to why an inverter shuts down on sunny days explains why.

Battery faults

  • F56 DC bus voltage too low. Usually the battery voltage is too low, for example after a long period of low charge or a power cut. The manual suggests charging the battery from solar or the grid and checking the battery management system (BMS).

  • F58 Battery communication lost. The inverter has lost contact with the battery’s BMS. Often a loose communication cable or a battery that has shut down. If it keeps coming back, it needs checking.

Our guides to why a battery isn’t charging and why a battery isn’t discharging cover other battery problems.

Panel and cabling faults: call an engineer

  • F23 AC leakage current. Leakage current to earth. The manual says a panel with an earth fault may be the cause.

  • F24 DC insulation impedance failure. The insulation between the panels or cables and earth has dropped, or the earth connection is poor.

  • F20 DC overcurrent. Too much current on the DC side, from the panels or battery. The manual suggests switching off the DC and AC switches, waiting a minute and switching back on. If it returns, it needs an engineer.

Don’t open the inverter, touch the DC cables or isolators, or change settings you’re unsure of.

Book a solar system inspection

Tell us what’s happening and one of our team will call you back to arrange a visit.

We install across London and up to around 50 miles out.

No obligation. We’ll call you back within one working day (Mon–Fri, 9am–5pm). We only use your details to deal with your enquiry. See our privacy policy.

Overload and inverter faults

  • F18 and F34 AC overcurrent. Usually too much load on the backup output. Turn off large appliances on the backup circuit and restart. Our guide to what keeps working in a power cut explains backup circuits.

  • F26 Bus bar unbalanced. The manual suggests waiting five minutes, then a full restart if it doesn’t clear.

  • F64 Heat sink high temperature. The inverter is too hot. Check nothing is blocking airflow. The manual suggests turning it off for 30 minutes before restarting.

  • F13 Working mode change. Usually appears after settings are changed. A restart normally clears it.

What you can safely check yourself

Illustration of the switches in a consumer unit, one of the checks you can safely make
  1. Note the code, the time it appeared and what was happening, for example a power cut or heavy appliance use.

  2. Check the solar or inverter breaker in your consumer unit and the AC isolator are on.

  3. Check whether there is a power cut in your area.

  4. Make sure nothing is blocking the inverter’s ventilation.

  5. Look at the battery’s charge level in the app.

If a code keeps coming back, don’t keep restarting the inverter. Get it looked at.

Repair or replace?

We diagnose the fault first, checking the panels, battery and cabling as well as the inverter. If the inverter or battery has failed and is out of warranty, replacing it with a new hybrid inverter and battery gives you a supported system with new warranties. We usually fit Solis, FoxESS or Hanchu. Our Solis guide and page on inverter replacement explain the options.

Frequently asked questions

Is F35 a fault with my inverter?

Usually not. It means the inverter can’t see the grid. Check for a power cut and that the breakers and isolators are on.

Why does my Sunsynk show F56 after a power cut?

The battery may have run very low during the cut. Once the grid returns or the sun comes up, it should recharge. If the code stays, have the battery checked.

Can I reset a Sunsynk fault myself?

A restart can clear some faults, following the order in the manual. If a fault keeps returning, the cause needs finding.

Do you work on Sunsynk systems you didn’t install?

Yes. We inspect and diagnose systems whoever installed them. For other brands, see our guides to Solis, FoxESS and Huawei fault codes.

Get your inverter checked

Book a solar system inspection and send us the fault code and a photo of the inverter label.

Book a solar system inspection

Tell us what’s happening and one of our team will call you back to arrange a visit.

We install across London and up to around 50 miles out.

No obligation. We’ll call you back within one working day (Mon–Fri, 9am–5pm). We only use your details to deal with your enquiry. See our privacy policy.

Latest Articles

Ready to Start Saving with Solar?

Get your free no-obligation quote today. Our experts will design the perfect system for your home.

Free Home Survey

MCS Certified

Reply in 1 Working Day

© 2026 Solar Panels London. All rights reserved.

SOLAR PANELS LONDON (SPL) LIMITED, registered in England and Wales, company number 14360308. Registered Office, 20 Rosslyn Crescent, Luton, LU3 2AU. SOLAR PANELS LONDON (SPL) LIMITED is an Introducer Appointed Representative of Shermin Finance Limited, FRN 727594, company number 01276121. Registered Office, Homeserve, Cable Drive, Walsall, WS2 7BN. Shermin Finance Limited act as a credit broker and is not a lender. Credit is subject to status and affordability.